Short answer
One kilowatt of panels on a south roof at 35° gives about 1,108 kWh a year in Kosiv, 1,031 in Yaremche and 1,042 in Vorokhta. December brings only 38-48 kWh a month against 117-130 in July. A 5 kW system with a 10 kWh battery in Kosiv hits its discharge limit on half of December days, so winter still needs the grid or a generator.
Most people who put solar panels on a mountain house have one thing in mind: keeping the lights on when the grid goes down. So the useful number is not the yearly total. It is what the panels give in December, when the day is short, the sun is low and a ridge to the south may hide it by early afternoon. We ran seven places between Kosiv and Vorokhta through PVGIS, the European Commission's free solar calculator, using satellite data for 2005-2023 and the shade cast by the mountains.
How much does 1 kW of panels give per year and in December?
Roughly 1,030-1,110 kWh a year for every kilowatt installed, with the panels facing south at 35°. Between villages the yearly gap is small, at most 7%. Between months it is huge. December yields 2.6 to 3.2 times less than July, and December is the month that decides whether a system is any use in winter.
| Place | Per year | December | July | December with no mountains |
|---|---|---|---|---|
| Kosiv | 1,108 | 44 | 130 | 44 |
| Verkhovyna | 1,097 | 48 | 124 | 48 |
| Sokolivka | 1,083 | 40 | 127 | 45 |
| Kosmach | 1,072 | 45 | 121 | 45 |
| Yavoriv | 1,054 | 39 | 124 | 45 |
| Vorokhta | 1,042 | 43 | 117 | 46 |
| Yaremche | 1,031 | 38 | 120 | 44 |
Verkhovyna gives the most in December of all seven, even though it lies deeper in the mountains than Kosiv. The satellite record shows the most December light at its point, and its southern horizon is low. Kosiv wins over the year thanks to its long sunny summer. Output also moves from year to year: in Kosiv the standard deviation is 43 kWh, so a poor summer costs about 4%.
A ridge to the south takes up to 15% of December's sun
The last column shows what the same panels would give on open flat land. In Kosiv, Kosmach and Verkhovyna there is almost no difference, because the southern horizon is low. In Yaremche, Yavoriv and Sokolivka the mountains take 13-15% of December output, in Vorokhta 6%. Over the year the loss is smaller, about 3% in Yaremche and Yavoriv, because the summer sun rides well above any ridge. These figures are for the village centre. A plot 600 metres away can be a different story, and we showed how differently the hills shade points within one village in our piece on winter sun on a mountain plot.
Which roof slope suits panels, and what east or west costs you
For the best yearly total in Kosiv, a roof faces south at 35-45°. If the system is there mainly for winter, though, steeper panels pay. Here is the same 1 kW in Kosiv at different angles and directions.
| Direction and tilt | Per year | January | December | Year against south 35° |
|---|---|---|---|---|
| South, 35° | 1,108 | 53 | 44 | baseline |
| South, 45° | 1,106 | 57 | 47 | -0.2% |
| South, 60° | 1,056 | 60 | 51 | -5% |
| South, 20° | 1,064 | 44 | 35 | -4% |
| South wall, 90° | 791 | 57 | 49 | -29% |
| South-east, 35° | 1,046 | 45 | 37 | -6% |
| South-west, 35° | 1,023 | 44 | 36 | -8% |
| East, 35° | 875 | 28 | 21 | -21% |
| West, 35° | 842 | 27 | 20 | -24% |
A steep roof loses in summer and wins in winter
At 60° the panels give 5% less over the year than at 35°, yet 17% more in December. Even panels hung flat on a south wall beat a 35° roof in December, 49 kWh against 44. The reason is the low sun: at midday in December it climbs only about 18° above the horizon in Kosiv, so a steep surface faces it almost square on. If the house has to ride out winter power cuts, that argues for a steep roof or a separate frame set at a high angle.
East and west roofs halve your December output
Over the year an east or west roof loses 21-24%, and plenty of owners accept that. In December, though, east gives 21 kWh against 44 facing south. If you are choosing a house design, or a plot where the ridge line can still be turned, settle this before the foundations go in. Nobody rotates a roof afterwards. How we take a house from design to handover is set out on our construction page.
How to run your own plot through PVGIS
- Open the tool and find the spotGo to re.jrc.ec.europa.eu/pvg_tools/en/, type the coordinates into the Lat/Lon box and press Go!. Take the coordinates from the cadastral map or from Google Maps by clicking on the plot. Make sure Calculated horizon is selected so the mountains are counted.
- Describe your panels on the GRID CONNECTED tabEnter Installed peak PV power in kilowatts, Slope, and Azimuth (0 is south, -90 east, 90 west). If the panels will sit on the roof, choose Roof added / Building integrated under Mounting position. In Kosiv that takes about 4% off the year, because the panels run hotter.
- Read December, not the annual figureThe results list output month by month. Multiply December by the number of kilowatts and compare it with what the house uses in a December. That is the honest answer to how far the system goes in winter.
- For running without the grid, use the OFF-GRID tabHere you set Battery capacity in watt-hours, Discharge cutoff limit (the PVGIS manual suggests 20% for lithium batteries) and Consumption per day. The tool reports the share of days in each month when the battery runs down to its limit.
Can panels and a battery carry a house through winter power cuts?
In summer, yes. In winter, no, unless the grid or a generator backs them up. We ran nine set-ups in OFF-GRID mode. A day counts when the battery drops to its 20% limit at least once. For the rest of that day the house runs on whatever the panels make in that hour, and in the evening that is nothing.
| Place and set-up | Daily use | December | January | July | Year |
|---|---|---|---|---|---|
| Kosiv: 3 kW, 5 kWh battery, 35° | 3 kWh | 59% | 43% | under 1% | 16% |
| Kosiv: 3 kW, 10 kWh battery, 35° | 3 kWh | 35% | 18% | 0% | 7% |
| Kosiv: 3 kW, 10 kWh battery, 35° | 5 kWh | 75% | 69% | 2% | 27% |
| Kosiv: 5 kW, 10 kWh battery, 35° | 5 kWh | 50% | 35% | under 1% | 13% |
| Kosiv: 5 kW, 10 kWh battery, 60° | 5 kWh | 47% | 33% | under 1% | 13% |
| Kosiv: 5 kW, 15 kWh battery, 35° | 5 kWh | 38% | 21% | 0% | 8% |
| Kosiv: 5 kW, 10 kWh battery, 35° | 8 kWh | 85% | 78% | 7% | 39% |
| Vorokhta: 5 kW, 10 kWh battery, 35° | 5 kWh | 53% | 39% | 0% | 14% |
| Yaremche: 5 kW, 10 kWh battery, 35° | 5 kWh | 59% | 42% | under 1% | 15% |
For off-grid systems PVGIS assumes an overall performance ratio of 0.67 and calls that a conservative estimate, so a real installation may do a little better. The pattern will not change. From April to September panels with a battery keep a house going almost every day, from November to January only part of the time. If a heat pump heats the house, work out its winter use separately, because it comes on top of these 3-5 kWh a day. We worked through heating costs without mains gas in a separate piece on wood, pellets and heat pumps.
What the model cannot see, and what to check on the plot
- Snow on the panels. PVGIS does not count the days panels spend under snow. Its manual only lists snow among the general 14% of losses. The mountains get deep snow, as our 30 winters of snow data around Kosiv show, so think about how you will clear the panels and whether you can reach them safely.
- Trees and neighbouring buildings. The tool builds its horizon from a terrain model, which has no idea about the spruces behind the fence or the barn next door. Stand where the panels will go and look south at midday in November or December.
- Satellite data on a grid of about 5 km. A valley floor and the slope above it get the same number, even though in winter the valley can sit in fog while the slope is in sun.
- Your real consumption. Check last winter's electricity bills, or list the appliances that must run during a cut and how many hours each one runs.
If you are still choosing a plot, put sun on the checklist next to road access, water and power. Plots on open south-facing slopes come up among our land listings in the Carpathians, and a PVGIS run for one exact spot takes a few minutes.
Frequently asked questions
Sources
- PVGIS, the solar calculator of the European Commission's Joint Research Centre. GRID CONNECTED and OFF-GRID tabs, PVGIS-SARAH3 data for 2005-2023, mountain shade from the terrain model; every figure in this article was run in November 2026
- PVGIS user manual. Where the 14% loss comes from and why snow is not modelled on its own, the 20% discharge limit for lithium batteries, the 0.67 performance ratio off-grid, the grid size of the satellite data